Key data
| Fluid | Argon (Ar) |
|---|---|
| CAS number | 7440-37-1 |
| Molar mass | 39.948 g/mol |
| Critical temperature | -122.46 °C (150.69 K) |
| Critical pressure | 48.63 bar (4.863 MPa) |
| Critical density | 535.6 kg/m³ |
| Triple point | -189.34 °C · 0.6889 bar |
| Normal boiling point (1 atm) | -185.85 °C |
| Equation of state | Tegeler et al. (1999), A New Equation of State for Argon Covering the Fluid Region for Temperatures From the Melting Line to 700 K at Pressures up to 1000 MPa, J. Phys. Chem. Ref. Data 28, 779-850. doi:10.1063/1.556037 |
| Viscosity correlation | Lemmon & Jacobsen (2004), Viscosity and Thermal Conductivity Equations for Nitrogen, Oxygen, Argon, and Air, Int. J. Thermophys. 25, 21-69. doi:10.1023/B:IJOT.0000022327.04529.f3 |
| Thermal conductivity correlation | Lemmon & Jacobsen (2004), Viscosity and Thermal Conductivity Equations for Nitrogen, Oxygen, Argon, and Air, Int. J. Thermophys. 25, 21-69. doi:10.1023/B:IJOT.0000022327.04529.f3 |
| Reference for h and s | same as CoolProp (reference state of the original equation) |
Reading the diagrams of argon
- P-h (pressure–enthalpy): the usual chart for refrigeration cycles. Heat exchanged at constant pressure is a horizontal distance; an ideal compression follows an isentrope.
- P-T: the saturation line separates liquid and vapour and ends at the critical point (-122.46 °C, 48.63 bar).
- T-s and h-s (Mollier): the two-phase dome, with the bubble line (saturated liquid) on its left and the dew line (saturated vapour) on its right.
- Vapour or gas? Both words describe the gaseous state. Below the critical temperature of argon (-122.46 °C), its gaseous phase is called a vapour: compression alone can condense it. Above that temperature it is called a gas, and a supercritical fluid when the pressure is also above the critical pressure (48.63 bar). The dash-dot lines of the diagrams mark these limits.
The selected state is kept when you change diagram, and the address of the page records it: copy the link to share a state.
Key facts about argon
The critical point of argon is at -122.46 °C and 48.63 bar, with a density of 535.6 kg/m³. At atmospheric pressure (1.01325 bar) it boils at -185.85 °C. Its triple point is at -189.34 °C and 0.6889 bar. Its molar mass is 39.948 g/mol.
Method and limits
Properties are computed with the equation of state of Tegeler et al. (1999), using the coefficients published in the open-source library CoolProp. The site's own engine reproduces CoolProp's values to better than one part in a hundred million on the tested states.
- Viscosity and thermal conductivity come from the correlations of Lemmon & Jacobsen (2004) and Lemmon & Jacobsen (2004), as implemented in CoolProp; they are shown for single-phase states only.
- Solid phases are not represented: below the triple point or at very high pressure near the melting line, results do not describe a real state.
See the credits and licences page for the sources.