Key data
| Fluid | Dry air |
|---|---|
| CAS number | — |
| Molar mass | 28.965 g/mol |
| Critical temperature | -140.62 °C (132.53 K) |
| Critical pressure | 37.86 bar (3.786 MPa) |
| Critical density | 342.7 kg/m³ |
| Lowest temperature of the equation | -213.40 °C |
| Bubble / dew point at 1 atm | -194.25 °C / -191.43 °C |
| Equation of state | Lemmon et al. (2000), Thermodynamic Properties of Air and Mixtures of Nitrogen, Argon, and Oxygen from 60 to 2000 K at Pressures to 2000 MPa, J. Phys. Chem. Ref. Data 29, 331-385. doi:10.1063/1.1285884 |
| Viscosity correlation | Lemmon & Jacobsen (2004), Viscosity and Thermal Conductivity Equations for Nitrogen, Oxygen, Argon, and Air, Int. J. Thermophys. 25, 21-69. doi:10.1023/B:IJOT.0000022327.04529.f3 |
| Thermal conductivity correlation | Lemmon & Jacobsen (2004), Viscosity and Thermal Conductivity Equations for Nitrogen, Oxygen, Argon, and Air, Int. J. Thermophys. 25, 21-69. doi:10.1023/B:IJOT.0000022327.04529.f3 |
| Reference for h and s | same as CoolProp (reference state of the original equation) |
Reading the diagrams of air
- P-h (pressure–enthalpy): the usual chart for refrigeration cycles. Heat exchanged at constant pressure is a horizontal distance; an ideal compression follows an isentrope.
- P-T: the saturation line separates liquid and vapour and ends at the critical point (-140.62 °C, 37.86 bar).
- T-s and h-s (Mollier): the two-phase dome, with the bubble line (saturated liquid) on its left and the dew line (saturated vapour) on its right.
- Vapour or gas? Both words describe the gaseous state. Below the critical temperature of air (-140.62 °C), its gaseous phase is called a vapour: compression alone can condense it. Above that temperature it is called a gas, and a supercritical fluid when the pressure is also above the critical pressure (37.86 bar). The dash-dot lines of the diagrams mark these limits.
The selected state is kept when you change diagram, and the address of the page records it: copy the link to share a state.
Key facts about air
The critical point of air is at -140.62 °C and 37.86 bar. At atmospheric pressure it starts boiling at -194.25 °C (bubble point) and is fully vaporised at -191.43 °C (dew point): a temperature glide of 2.82 K. Its mean molar mass is 28.965 g/mol.
Method and limits
Properties are computed with the equation of state of Lemmon et al. (2000), using the coefficients published in the open-source library CoolProp. The site's own engine reproduces CoolProp's values to better than one part in a hundred million on the tested states.
- Viscosity and thermal conductivity come from the correlations of Lemmon & Jacobsen (2004) and Lemmon & Jacobsen (2004), as implemented in CoolProp; they are shown for single-phase states only.
- Solid phases are not represented: below the triple point or at very high pressure near the melting line, results do not describe a real state.
- Air is a blend modelled as a single pseudo-pure fluid: inside the two-phase region, temperature and properties are interpolated linearly between the bubble and dew points, as in CoolProp.