Rankine cycle (steam power plant)

The Rankine cycle is the cycle of steam power plants: water is pumped, boiled and superheated in the boiler, expanded in a turbine, then condensed. Set the pressures, the steam temperature and the machine efficiencies, and follow the cycle on the T-s and Mollier diagrams.

Parameters

Results

Thermal efficiency33.4 %
Turbine work (3→4)1078.8kJ/kg
Pump work (1→2)10.07kJ/kg
Net work1068.8kJ/kg
Heat received in the boiler (2→3)3197.5kJ/kg
Heat rejected in the condenser (4→1)2128.7kJ/kg
Steam quality at the turbine outlet0.890
Back work ratio (pump / turbine)0.9 %
Carnot efficiency between T₁ and T₃58.7 %

States of the cycle

PointPressurebarTemperature°CEnthalpykJ/kgEntropykJ/(kg·K)Quality x
10.145.81191.810.64920.000
28046.56201.890.6555—
380500.003399.376.7264—
40.145.812320.557.32330.890
Temperature–entropy diagram · Open the interactive diagram
Enthalpy–entropy (Mollier) diagram · Open the interactive diagram

The four processes

  1. 1→2 Pump Saturated liquid from the condenser is pumped up to the boiler pressure. The ideal compression is isentropic; the work, w_P = h₂ − h₁, is small because a liquid is nearly incompressible.
  2. 2→3 Boiler Heating at constant pressure: the water warms up to boiling, evaporates (the horizontal plateau on the T-s diagram) and is superheated. Heat received: q_in = h₃ − h₂.
  3. 3→4 Turbine The steam expands down to the condenser pressure: isentropic (vertical) in the ideal cycle, with an isentropic efficiency in a real turbine. Work produced: w_T = h₃ − h₄.
  4. 4→1 Condenser The wet steam condenses at constant pressure and temperature, rejecting q_out = h₄ − h₁ to the cold source (river, sea or cooling tower).

Efficiency and how to raise it

The thermal efficiency is η = (w_T − w_P) / q_in = 1 − q_out / q_in. It stays below the Carnot efficiency between the same extreme temperatures because the water receives heat at increasing temperature, much of it well below the steam temperature.

The steam quality at the turbine outlet should not fall much below about 0.9 (a usual rule of thumb): water droplets erode the last blades. Superheating and reheating keep it high.

Example

With a boiler at 30 bar and 350 °C and a condenser at 0.75 bar, the ideal cycle (efficiencies 100 %) gives an efficiency of 26.0 % and a quality of 0.886 at the turbine outlet: the result of the classic textbook example (Çengel & Boles, Thermodynamics: An Engineering Approach, Example 10-1), which this page reproduces.

Method

Water and steam properties from IAPWS-IF97 (same engine as the steam table); the ideal textbook example above is part of the site's automated tests.

Course refresher: thermodynamic properties