Thermodynamic properties: definitions, physical meaning and equations

This course presents the properties computed by this site — pressure, temperature, specific volume, internal energy, enthalpy, entropy, specific heats, vapour quality — with their definition, their physical meaning and the equations that link them. The worked values are computed by the same engines as the site's calculators.

System, state and properties

A system is the portion of matter under study, separated from the rest (the surroundings) by a boundary. It is closed if no matter crosses the boundary (gas in a cylinder), open if matter flows through it (turbine, heat exchanger), isolated if it exchanges neither matter nor energy.

The state of a system at equilibrium is described by properties (state functions): pressure, temperature, volume, internal energy, enthalpy, entropy… Their change between two states depends only on those states, not on the path. Work WW and heat QQ, by contrast, are not properties: they are energy transfers and depend on the process. Hence dUdU for a small change of internal energy, but δW\delta W and δQ\delta Q for small amounts transferred.

  • An extensive property is proportional to the amount of matter: volume VV, internal energy UU, enthalpy HH, entropy SS.
  • An intensive property is not: pressure pp, temperature TT.
  • A specific property (lower case) is an extensive property divided by the mass: v=V/mv = V/m, u=U/mu = U/m, h=H/mh = H/m, s=S/ms = S/m. These are the values given in tables and on this site.

How many properties fix the state? Gibbs' phase rule gives the number of independent intensive properties (degrees of freedom) of a system of CC components and φ\varphi phases at equilibrium:

F=C−φ+2F = C - \varphi + 2

For a pure substance (C=1C = 1) in a single phase, F=2F = 2: two properties, for example pp and TT, are enough — which is why the calculators ask for two inputs. In a liquid–vapour mixture, F=1F = 1: the pressure sets the boiling temperature, and another property (quality, enthalpy…) is needed to locate the state. At the triple point, where three phases coexist, F=0F = 0: pp and TT are fixed by nature.

Pressure, temperature and specific volume

Pressure is the force exerted by the fluid per unit area, normal to the surface:

p=FAp = \frac{F}{A}

Its SI unit is the pascal (1 Pa = 1 N/m²); the bar (1 bar = 10⁵ Pa) and the megapascal (1 MPa = 10 bar) are common. At the microscopic scale it results from molecules hitting the walls. Tables use absolute pressure; a gauge often reads gauge pressure: pabs=pgauge+patmp_\mathrm{abs} = p_\mathrm{gauge} + p_\mathrm{atm}, with 1 atm = 101 325 Pa.

Temperature is the property shared by two systems in thermal equilibrium (zeroth law of thermodynamics). Thermodynamics uses the absolute temperature TT, in kelvins:

T(K)=θ(°C)+273.15T(\mathrm{K}) = \theta(\mathrm{°C}) + 273.15

Since 2019 the kelvin has been defined by fixing the Boltzmann constant, k=1.380649×10−23k = 1.380\,649 \times 10^{-23} J/K (International System of Units, 9th edition). Temperature measures molecular agitation: in an ideal gas, the mean translational kinetic energy of a molecule is 32kT\frac{3}{2} k T.

Specific volume v=V/mv = V/m (m³/kg) is the inverse of density ρ=1/v\rho = 1/v (kg/m³). Values computed by the site: liquid water at 25 °C and 1 bar has a density of 997.0 kg/m³, air at 300 K and 1 bar 1.162 kg/m³.

Work and heat: energy transfers

A system exchanges energy with its surroundings in two forms:

  • work WW, an organised transfer associated with a moving force (piston, turbine shaft, electric current);
  • heat QQ, a disorganised transfer driven by a temperature difference.

Sign convention: in this course, any energy received by the system is positive (the IUPAC convention). Many engineering textbooks instead count the work done by the system as positive and write ΔU=Q−W\Delta U = Q - W: both conventions describe the same physics, only the signs differ. The cycle pages of the site avoid the ambiguity by giving named positive quantities ("turbine work", "heat received").

The pressure work received by a system whose volume changes by dVdV is δW=−pextdV\delta W = -p_\mathrm{ext}\,dV. For a slow (quasi-static) process, pext=pp_\mathrm{ext} = p and:

W=−∫V1V2pdVW = -\int_{V_1}^{V_2} p\,dV

On a pressure–volume diagram, the work is the area under the process curve and the net work of a cycle the area it encloses — see the Otto cycle on the P-v diagram.

Internal energy U and the first law

Internal energy UU is the energy stored in matter at the microscopic scale: kinetic energy of translation, rotation and vibration of the molecules, potential energy of their interactions, chemical and nuclear energy. It excludes the kinetic and potential energy of the system as a whole. Unit: joule (J); specific value uu in kJ/kg.

The first law expresses the conservation of energy. For a closed system:

ΔU+ΔEk+ΔEp=W+Q\Delta U + \Delta E_\mathrm{k} + \Delta E_\mathrm{p} = W + Q

For a system at rest, ΔU=W+Q\Delta U = W + Q, or per unit mass du=δw+δqdu = \delta w + \delta q. Over a complete cycle the system returns to its initial state: ΔU=0\Delta U = 0, so W+Q=0W + Q = 0. The net work delivered by an engine equals the net heat it receives — work cannot be produced from nothing.

At constant volume (no pressure work), all the heat received raises the internal energy. This defines the specific heat at constant volume:

cv=(∂u∂T)vc_v = \left(\frac{\partial u}{\partial T}\right)_v

The subscript vv indicates the property held constant in the derivative.

Enthalpy H

Enthalpy is defined by:

H=U+pVH = U + pVh=u+pvh = u + pv

It is a property, since it is built from properties. It has two interpretations, which explain why it is the most used property in energy engineering.

1. Heat received at constant pressure. If the pressure is constant and the only work is pressure work, W=−pΔVW = -p\,\Delta V and the first law gives ΔU=Q−pΔV\Delta U = Q - p\,\Delta V, hence:

ΔH=Qp\Delta H = Q_p

In a boiler, a condenser or an evaporator, which work at nearly constant pressure, the heat exchanged per kilogram is simply the enthalpy difference: q=h2−h1q = h_2 - h_1.

2. Energy carried by a flowing fluid. Pushing 1 kg of fluid into a machine against the pressure pp takes the flow work pvpv. Enthalpy h=u+pvh = u + pv is therefore the energy brought in by each kilogram entering. For an open system in steady state with mass flow rate m˙\dot{m}, the first law reads:

Q˙+W˙s=m˙[(h2−h1)+c22−c122+g(z2−z1)]\dot{Q} + \dot{W}_\mathrm{s} = \dot{m}\left[(h_2 - h_1) + \frac{c_2^2 - c_1^2}{2} + g\,(z_2 - z_1)\right]

where W˙s\dot{W}_\mathrm{s} is the shaft power received (through moving parts: shaft, blades), cc the velocity and zz the elevation. Kinetic and potential energy changes are often negligible, which gives the basic balances of the machines:

  • adiabatic turbine: work produced wT=h1−h2w_\mathrm{T} = h_1 - h_2;
  • adiabatic compressor or pump: work received w=h2−h1w = h_2 - h_1;
  • heat exchanger: q=h2−h1q = h_2 - h_1;
  • expansion valve (adiabatic, no work): h2=h1h_2 = h_1, the isenthalpic throttling of the refrigeration cycle.

The specific heat at constant pressure is defined by:

cp=(∂h∂T)pc_p = \left(\frac{\partial h}{\partial T}\right)_p

For liquid water at 25 °C, cpc_p = 4.182 kJ/(kg·K); for air at 300 K and 1 bar, 1.006 kJ/(kg·K).

During a phase change at constant pressure, the temperature stays fixed but the enthalpy rises by the enthalpy of vaporisation (latent heat) hfg=hg−hfh_{fg} = h_g - h_f. At standard atmospheric pressure, water boils at 99.97 °C with hfgh_{fg} = 2256.5 kJ/kg, about 5.4 times the energy needed to heat liquid water from 0 to 100 °C (419.0 kJ/kg).

Entropy S and the second law

Entropy is defined by Clausius from reversible heat transfers:

dS=δQrevTdS = \frac{\delta Q_\mathrm{rev}}{T}

Unit: J/K; specific value ss in kJ/(kg·K). A reversible process is an ideal, infinitely slow, frictionless process that could be run backwards, returning both the system and the surroundings to their initial state.

The second law reads, for a closed system whose boundary is at temperature TbT_\mathrm{b} where heat crosses it:

ΔS=∫δQTb+Sgen\Delta S = \int \frac{\delta Q}{T_\mathrm{b}} + S_\mathrm{gen}Sgen≥0S_\mathrm{gen} \geq 0

Entropy changes for two reasons: the entropy carried by the heat transferred, and the entropy generated SgenS_\mathrm{gen}, positive in every real process and zero only in the reversible limit. Irreversibilities come from friction, heat transfer across a finite temperature difference, mixing, free expansion and throttling. For an isolated system, ΔS≥0\Delta S \geq 0: entropy can only increase. For an open system in steady state:

m˙(s2−s1)=∑kQ˙kTk+S˙gen\dot{m}\,(s_2 - s_1) = \sum_k \frac{\dot{Q}_k}{T_k} + \dot{S}_\mathrm{gen}

Statistical interpretation. Boltzmann related entropy to the number Ω\Omega of microscopic states compatible with the observed macroscopic state:

S=kln⁡ΩS = k \ln \Omega

Entropy thus measures how spread out the energy is over the microscopic states; the familiar picture of "disorder" is a simplified version of this.

On the T-s diagram. For a reversible process, q=∫Tdsq = \int T\,ds: the heat transferred is the area under the curve, and the net work of a cycle the area it encloses (see the Carnot cycle, a rectangle). A reversible adiabatic process is isentropic: a vertical line. Real machines depart from it; the departure is measured by the isentropic efficiency, where the subscript ss denotes the state reached by the isentropic process down (or up) to the same pressure:

ηs,turbine=h1−h2h1−h2s\eta_{s,\mathrm{turbine}} = \frac{h_1 - h_2}{h_1 - h_{2s}}ηs,compressor=h2s−h1h2−h1\eta_{s,\mathrm{compressor}} = \frac{h_{2s} - h_1}{h_2 - h_1}

During a phase change, TT and pp are constant and the heat received is hfgh_{fg}, so sfg=hfg/Tsats_{fg} = h_{fg}/T_\mathrm{sat}. For water at atmospheric pressure: 2256.5 / 373.12 = 6.0477 kJ/(kg·K), the value given directly by the saturated steam table (sg−sfs_g - s_f = 6.0477 kJ/(kg·K)).

The Gibbs relations

Combining the first and second laws for a reversible process (δq=Tds\delta q = T\,ds, δw=−pdv\delta w = -p\,dv) gives the two fundamental relations:

Tds=du+pdvT\,ds = du + p\,dvTds=dh−vdpT\,ds = dh - v\,dp

Since they relate properties only, they hold for any process between two equilibrium states, even an irreversible one. They allow ss to be computed from uu, hh, pp and vv.

Application: why the pump uses so little work. For an isentropic (ds=0ds = 0) adiabatic compression, the second relation gives the work received per kilogram:

w=∫12vdp≈v(p2−p1)w = \int_1^2 v\,dp \approx v\,(p_2 - p_1)

the approximation holding for a nearly incompressible liquid. Pumping saturated water from 0.05 bar (32.9 °C, vv = 0.001005 m³/kg) to 100 bar takes about 10.0 kJ/kg, a few tenths of a percent of the heat received in the boiler. Compressing vapour, whose specific volume is hundreds or thousands of times larger, would cost far more: this is the point of the Rankine cycle, which condenses the steam completely before pumping it.

Helmholtz and Gibbs energies, equations of state

Two more properties are built from entropy:

a=u−Tsa = u - Tsg=h−Tsg = h - Ts

the Helmholtz energy aa and the Gibbs energy gg. Their differentials follow from the Gibbs relations, for example dg=−sdT+vdpdg = -s\,dT + v\,dp.

Liquid–vapour equilibrium. At given TT and pp, two phases are in equilibrium when their specific Gibbs energies are equal, gf=ggg_f = g_g. Differentiating this equality along the saturation curve gives the Clapeyron equation:

dpsatdT=hfgTvfg\frac{dp_\mathrm{sat}}{dT} = \frac{h_{fg}}{T\,v_{fg}}

For water at 100 °C, the slope of the saturation curve computed directly is 3.619 kPa/K, and the Clapeyron equation applied to the phase properties gives 3.619 kPa/K: the formulation used by the site is consistent.

Modern equations of state. The reference formulations of fluids (those of this site, taken from the CoolProp library) give the Helmholtz energy a(T,ρ)a(T, \rho) as a single function. Every other property follows by differentiation:

p=ρ2(∂a∂ρ)Tp = \rho^2 \left(\frac{\partial a}{\partial \rho}\right)_Ts=−(∂a∂T)ρs = -\left(\frac{\partial a}{\partial T}\right)_\rhou=a+Tsu = a + Tsh=u+pρh = u + \frac{p}{\rho}

For water, the industrial formulation IAPWS-IF97 uses the Gibbs energy g(p,T)g(p, T) for the liquid and the vapour, and the Helmholtz energy a(ρ,T)a(\rho, T) near the critical point. The sources of each fluid are listed on the sources page.

Ideal gas and real gases

At low pressure, gas molecules are far enough apart for their interactions to be negligible. The gas then follows the ideal-gas equation of state:

pv=rTpv = rTr=RMr = \frac{R}{M}

with RR = 8.314 462 618… J/(mol·K), the molar gas constant (exact since 2019, product of the Avogadro and Boltzmann constants), and MM the molar mass. For air, MM = 28.965 g/mol, so rr = 287.05 J/(kg·K).

The internal energy and enthalpy of an ideal gas depend on temperature only (Joule's law):

du=cvdTdu = c_v\,dTdh=cpdTdh = c_p\,dTcp−cv=rc_p - c_v = rγ=cpcv\gamma = \frac{c_p}{c_v}

The third equality is Mayer's relation. For air at 300 K and 1 bar, the reference equation of state gives cp−cvc_p - c_v = 288.4 J/(kg·K), close to rr, and γ\gamma = 1.402: under these conditions air behaves almost as an ideal gas.

With constant specific heats, the entropy change and the isentropic (reversible adiabatic) process read:

s2−s1=cpln⁡T2T1−rln⁡p2p1s_2 - s_1 = c_p \ln\frac{T_2}{T_1} - r \ln\frac{p_2}{p_1}
pvγ=constpv^\gamma = \mathrm{const}T2T1=(p2p1)γ−1γ\frac{T_2}{T_1} = \left(\frac{p_2}{p_1}\right)^{\frac{\gamma - 1}{\gamma}}

These are the relations of the air-standard cycles (Brayton, Otto, Diesel). The site's cycle pages do not use these approximations: they compute air with its full equation of state, and the differences stay small as long as temperatures are moderate.

Real gases. The departure from ideal-gas behaviour is measured by the compressibility factor:

Z=pvrTZ = \frac{pv}{rT}

Z=1Z = 1 for an ideal gas. Air at 300 K and 1 bar has ZZ = 0.9997. Steam at 400 °C has ZZ = 0.999 at 1 bar but ZZ = 0.851 at 100 bar: in a power plant, steam is far from an ideal gas, hence the use of tables and charts.

Liquid and vapour: saturation and quality

At a given pressure, a pure substance boils at a fixed temperature, the saturation temperature. Subscript ff denotes saturated liquid (about to boil) and gg saturated vapour (about to condense). In between, the fluid is a liquid–vapour mixture, characterised by its quality, the mass fraction of vapour:

x=mgmf+mgx = \frac{m_g}{m_f + m_g}

Every specific property of the mixture (vv, uu, hh, ss) is a weighted average, the lever rule:

h=hf+xhfgh = h_f + x\,h_{fg}s=sf+xsfgs = s_f + x\,s_{fg}v=vf+x(vg−vf)v = v_f + x\,(v_g - v_f)

Example: wet steam of quality 0.9 at 0.05 bar (32.9 °C) has an enthalpy of 2318.5 kJ/kg.

On the diagrams these states fill the saturation dome, capped by the critical point, beyond which liquid and vapour can no longer be distinguished. For water, TcT_c = 647.096 K (373.946 °C) and pcp_c = 22.064 MPa; the triple point, where ice, water and vapour coexist, is at 273.16 K and 611.657 Pa (IAPWS values). Quality only makes sense under the dome: a subcooled liquid or a superheated vapour is described by two properties such as pp and TT. For a compressed liquid the approximation h(T,p)≈hf(T)h(T, p) \approx h_f(T) is often used, the effect of pressure being small.

See the dome on the T-s diagram of water, the Mollier diagram and the P-h diagram.

Absolute values and reference state

Only differences in internal energy, enthalpy and entropy have a physical meaning in balances. Their absolute values depend on a reference state chosen by convention:

  • for water (IAPWS), u=0u = 0 and s=0s = 0 for saturated liquid at the triple point, which gives h=pvh = pv ≈ 0.000612 kJ/kg;
  • for refrigerants, the convention of the International Institute of Refrigeration (IIR) sets hh = 200 kJ/kg and ss = 1 kJ/(kg·K) for saturated liquid at 0 °C — the one used on the site's fluid pages, for example for R134a.

In practice: never mix values of hh or ss from different tables without checking that they share the same reference state. Differences, however, are the same whatever the convention.

Efficiency, COP and the Carnot limit

For an engine receiving qinq_\mathrm{in} from a hot source and rejecting qoutq_\mathrm{out} to a cold one (positive values), the first law over a cycle gives wnet=qin−qoutw_\mathrm{net} = q_\mathrm{in} - q_\mathrm{out}, and the thermal efficiency is:

η=wnetqin=1−qoutqin\eta = \frac{w_\mathrm{net}}{q_\mathrm{in}} = 1 - \frac{q_\mathrm{out}}{q_\mathrm{in}}

The second law limits this efficiency. Over a cycle the entropy of the fluid returns to its initial value; with sources at temperatures THT_H and TLT_L, the entropy balance gives qout/TL=qin/TH+sgenq_\mathrm{out}/T_L = q_\mathrm{in}/T_H + s_\mathrm{gen}, with sgen≥0s_\mathrm{gen} \geq 0. Hence the Carnot efficiency, the maximum, reached only by a reversible cycle:

η≤ηCarnot=1−TLTH\eta \leq \eta_\mathrm{Carnot} = 1 - \frac{T_L}{T_H}

For a refrigerator or a heat pump, the coefficient of performance (COP) is used: the useful effect divided by the work input, with qH=qL+wq_H = q_L + w:

COPcooling=qLw≤TLTH−TL\mathrm{COP}_\mathrm{cooling} = \frac{q_L}{w} \leq \frac{T_L}{T_H - T_L}COPheating=qHw=COPcooling+1\mathrm{COP}_\mathrm{heating} = \frac{q_H}{w} = \mathrm{COP}_\mathrm{cooling} + 1

A COP above 1 breaks no law: the machine does not create energy, it moves heat. These quantities are computed on each cycle page (links at the bottom).

Exergy: the quality of energy

The first law says that energy is conserved; the second, that it degrades. Exergy measures the part of energy that can be converted into work, given the environment (at T0T_0, p0p_0). For a flowing fluid, the specific flow exergy is:

ψ=(h−h0)−T0(s−s0)+c22+gz\psi = (h - h_0) - T_0\,(s - s_0) + \frac{c^2}{2} + g\,z

where subscript 0 denotes the fluid in equilibrium with the environment. Every irreversibility destroys exergy in proportion to the entropy generated (Gouy–Stodola theorem):

E˙xdestroyed=T0S˙gen\dot{E}x_\mathrm{destroyed} = T_0\,\dot{S}_\mathrm{gen}

A kilojoule of steam at 500 °C is therefore worth much more than a kilojoule of lukewarm water: it holds more exergy.

Transport properties

The site's calculators also give properties that belong to heat and momentum transfer rather than equilibrium thermodynamics: they are used to size pipes and heat exchangers.

  • Dynamic viscosity μ\mu (Pa·s): resistance of the fluid to shear. Kinematic viscosity: ν=μ/ρ\nu = \mu/\rho (m²/s).
  • Thermal conductivity λ\lambda (W/(m·K)): ability to conduct heat (Fourier's law, heat flux −λdT/dx-\lambda\,dT/dx).
  • Prandtl number, dimensionless, ratio of momentum diffusion to heat diffusion:
Pr=μcpλ\mathrm{Pr} = \frac{\mu\,c_p}{\lambda}

For water at 25 °C and 1 bar: μ\mu = 0.890 mPa·s, λ\lambda = 0.607 W/(m·K), Pr = 6.14.

Summary

PropertySymbolSI unit (specific)Physical meaning
PressureppPaForce per unit area
TemperatureTTKMolecular agitation; equal between systems in thermal equilibrium
Specific volumev=1/ρv = 1/\rhom³/kgVolume taken by 1 kg
Internal energyuuJ/kgMicroscopic energy of matter
Enthalpyh=u+pvh = u + pvJ/kgEnergy carried by a flow; heat at constant pressure
EntropyssJ/(kg·K)Spreading of energy; generated by irreversibilities
Specific heatscpc_p, cvc_vJ/(kg·K)Energy to raise 1 kg by 1 K
Qualityxx—Mass fraction of vapour
Compressibility factorZ=pv/(rT)Z = pv/(rT)—Departure from ideal gas
Helmholtz and Gibbs energiesaa, ggJ/kgThermodynamic potentials; phase equilibrium
Exergyψ\psiJ/kgPart of energy convertible into work

Sources

  • Y. A. Çengel, M. A. Boles, Thermodynamics: An Engineering Approach, McGraw-Hill (reference textbook for balances, cycles and exergy).
  • IUPAC, Quantities, Units and Symbols in Physical Chemistry ("Green Book"), 3rd edition, 2007: convention ΔU=Q+W\Delta U = Q + W.
  • BIPM, The International System of Units, 9th edition, 2019: definition of the kelvin and exact values of kk and RR.
  • IAPWS R7-97(2012), industrial formulation IAPWS-IF97 for water and steam (critical point, triple point, reference state).
  • R. Span, Multiparameter Equations of State, Springer, 2000: equations of state in Helmholtz energy.
  • The references of each computed fluid: sources page.

The numerical values on this page are computed when the site is built, with IAPWS-IF97 (water) and the reference equations of state (air, R134a), the same as in the calculators.

Put it into practice: the cycles