Stirling cycle (external-combustion engine)

The Stirling engine is a closed-cycle engine heated from outside, so any heat source can drive it: a burner, concentrated sunlight, waste heat. Its ideal cycle has two isothermal and two constant-volume processes; a regenerator stores the heat released during cooling and returns it during heating. Choose the gas, the temperatures, the compression ratio and the regenerator effectiveness.

Parameters

Results

Thermal efficiency52.3 %
Carnot efficiency between TL and TH65.3 %
Efficiency without regenerator18.9 %
Net work116.1kJ/kg
Heat supplied from outside221.9kJ/kg
Heat rejected to the cold source105.7kJ/kg
Heat stored and returned by the regenerator393.1kJ/kg
Maximum pressure (3)58.92bar

States of the cycle

PointPressurebarTemperature°CSpecific volumem³/kgInternal energykJ/kgEnthalpykJ/kgEntropykJ/(kg·K)
11030.00.0868340.7427.53.2342
219.95930.00.0434338.7425.43.0295
358.923600.00.0434776.31032.03.8314
429.163600.00.0868777.51030.64.0346
Pressure–specific volume diagram (P-v)
Temperature–entropy diagram · Open the interactive diagram

The four processes

  1. 1→2 Isothermal compression The gas is compressed at the constant temperature TL and gives heat to the cold source: q = TL (s₂ − s₁), negative.
  2. 2→3 Heating at constant volume The gas flows through the regenerator to the hot side: its temperature rises from TL to TH at constant volume. The heat u₃ − u₂ comes from the regenerator, and from outside for the part the regenerator cannot supply.
  3. 3→4 Isothermal expansion The gas expands at the constant temperature TH and takes q = TH (s₄ − s₃) from the hot source: this is the stroke that produces the work.
  4. 4→1 Cooling at constant volume The gas flows back through the regenerator to the cold side and leaves its heat there, cooling from TH to TL at constant volume.

Efficiency and regenerator

With a perfect regenerator (100 %), the heat exchanged at constant volume stays inside the engine: heat is taken only at TH and rejected only at TL, so the efficiency of the ideal cycle equals the Carnot efficiency 1 − TL/TH. This is exact for an ideal gas; with a real gas the two constant-volume heats differ slightly, hence a small gap. Without regenerator the efficiency is much lower: compare the values in the results.

Without regenerator the efficiency also depends on the gas: a monatomic gas such as argon has a smaller heat capacity and needs less heat on 2→3. Efficient engines use helium or hydrogen, whose low viscosity and high thermal conductivity allow fast heat transfer; the site has no equation of state for helium.

Real engines

The pistons move continuously, so the processes are neither exactly isothermal nor exactly at constant volume, and the heat exchangers, the regenerator and the dead volumes cause losses: real engines are well below the ideal cycle. Stirling engines are quiet and accept any heat source; they are used in solar dish systems and in some submarines, and, run in reverse, as cryocoolers.

Example

Between 30 °C and 600 °C with air, a compression ratio of 2 and 10 bar, this page gives 65.2 % with a perfect regenerator (Carnot efficiency: 65.3 %), 52.3 % with a 90 % regenerator and 18.9 % without regenerator.

Method

Gas properties from the reference equations of state of the site's engine (air: Lemmon et al., 2000; hydrogen, nitrogen and argon: see Credits), real gas. Ideal cycle: no losses other than the regenerator, which returns a share ε of the smaller of the two constant-volume heats.