Combined gas–steam cycle

A combined-cycle power plant chains two cycles: the exhaust of a gas turbine (Brayton cycle), still at roughly 450 to 650 °C, raises steam in a heat recovery steam generator (HRSG) for a steam turbine (Rankine cycle). Set the gas turbine, the steam conditions and the pinch of the HRSG: the page computes the steam flow per kg of air and the efficiency of the whole plant.

Parameters

Results

Combined-cycle efficiency58.3 %
Gas turbine efficiency (alone)40.8 %
Steam cycle efficiency (alone)37.3 %
Gas turbine net work, per kg of air424.7kJ/kg
Steam cycle net work, per kg of air182.4kJ/kg
Total net work, per kg of air607.1kJ/kg
Heat added in the combustion chamber1041.4kJ/kg
Steam flow per kg of air0.147kg/kg
Gas turbine exhaust temperature (4)601.5°C
Stack temperature (5)142.0°C
Smallest temperature difference in the HRSG10.0K
Carnot efficiency between T₁ and T₃81.7 %

States of the cycle

PointPressurebarTemperature°CEnthalpykJ/kgEntropykJ/(kg·K)Quality x
Air and exhaust gas (gas turbine)
1115.00414.383.8500—
216400.11811.183.9231—
3161300.001852.544.8963—
41601.461031.015.0060—
51142.01542.654.2186—
Water and steam (steam cycle)
60.0532.88137.770.47630.000
710033.72150.300.4844—
8100540.003476.876.7277—
90.0532.882221.997.28690.860
Temperature–entropy diagram of the gas turbine (air) · Open the interactive diagram
Temperature–entropy diagram of the steam cycle (water) · Open the interactive diagram
Temperature profiles in the heat recovery steam generator

The four parts of the plant

  1. 1→4 Gas turbine Air is compressed (1→2), heated by combustion at constant pressure (2→3) and expanded in the turbine (3→4): the Brayton cycle. The exhaust leaves the turbine still hot, at T₄.
  2. 4→5 Heat recovery steam generator The exhaust gas cools from T₄ to the stack temperature T₅ while heating the water at constant pressure (7→8): economiser (liquid heated up to boiling), evaporator, superheater.
  3. 8→9 Steam turbine The superheated steam expands in the steam turbine, which produces additional work without burning more fuel.
  4. 9→6→7 Condenser and pump The steam condenses at low pressure (9→6) and the pump returns the water to the HRSG (6→7), closing the Rankine cycle.

Efficiency

All the heat comes from the fuel burnt in the gas turbine; the steam cycle runs on heat that a simple gas turbine would release to the atmosphere. Per kg of air, η = (w_gas + y · w_steam) / q_in, where y is the steam flow per kg of air. Each cycle alone stays around 35 to 40 %, but together they exceed 55 %, and the best plants announce more than 60 %: combined cycles are the most efficient large thermal power plants.

Pinch point

In the HRSG the water heats up, boils at constant temperature, then is superheated, while the gas cools down steadily. The two temperature profiles come closest where evaporation starts: this pinch point, often about 10 K, sets the steam flow. A smaller pinch recovers more heat but needs a larger, costlier exchanger.

Below the pinch the gas can only be cooled down to the stack temperature T₅. This is why large plants use two or three pressure levels, which bring the water profile closer to the gas profile; this page models a single pressure level.

Example

In the classic textbook example (Çengel & Boles, Thermodynamics: An Engineering Approach, chapter on vapour and combined power cycles), the gas turbine has a pressure ratio of 8, air at 300 K, a turbine inlet at 1300 K and efficiencies of 80 % (compressor) and 85 % (turbine). The ideal steam cycle runs between 7 MPa and 5 kPa with steam at 500 °C, and the exhaust leaves the HRSG at 450 K. The book finds 0.131 kg of steam per kg of gas and a combined efficiency of 48.7 %, against 26.6 % for the gas turbine alone. The site's tests reproduce these values; the page itself sets the steam flow by the pinch rather than by the stack temperature.

Method

Air from the reference equation of state of air (Lemmon et al., 2000), at 1 bar at the compressor inlet; water and steam from IAPWS-IF97. Air-standard gas turbine (the exhaust gas is treated as air), single-pressure HRSG without heat losses, pump efficiency 80 %.

Course refresher: thermodynamic properties